Description:
|
sonetMediumValidIntervals OBJECT-TYPE
SYNTAX Integer32 (0..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of previous 15-minute intervals for which data was collected.
A SONET/SDH interface must be capable of supporting at least n intervals.
The minimum value of n is 4.
The default of n is 32.
The maximum value of n is 96.
The value will be <n> unless the measurement was (re-)started within the last (<n>*15) minutes, in which case the value will be the number of complete 15 minute intervals for which the agent has at least some data. In certain cases (e.g., in the case where the agent is a proxy) it is possible that some intervals are unavailable. In this case, this interval is the maximum interval number for which data is available."
|
|
Information:
|
Automatically extracted from IETF RFC 3592.
|
|
Disclaimer: The owner of this site does not warrant or assume any liability or responsibility for the accuracy, completeness, or usefulness of any information available on this page (for more information, please read the complete disclaimer).