Description:
|
sdlcPortAdminACTIVTO OBJECT-TYPE
SYNTAX TimeInterval
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This parameter defines the period of time (in
1/100ths of a second) that the port will allow a
switched line to remain inactive before
disconnecting. A switched line is considered
to be inactive if there are no I-Frames being
transferred. A value of zero indicates no
timeout. Depending on the implementation, a
write operation to this administered value may
not take effect until the port is cycled
inactive.
This object only has meaning for SDLC ports
where sdlcPortAdminType == switched
The object descriptor contains the name of an
NCP configuration parameter, ACTIVTO. Please
note that the value of this object represents
1/100ths of a second while the NCP ACTIVTO is
represented in seconds."
DEFVAL { 0 }
|
|