Description:
|
statusCheckFrequency OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates how often the Status thread should
gather all status and error data from all discovered Symmetrixes.
For each director or device error condition, a trap will be
generated (Trap 1 or 2) to all registered trap clients.
Initialize at startup from a separate 'config' file.
Recommended default is 60 seconds (1 minute). A value less than 60
will disable the thread. Minimum frequency is 60 seconds."
|
|