bgp4V2PeerHoldTimeConfigured OBJECT-TYPE
SYNTAX Unsigned32 ( 0 | 3..65535 )
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Time interval (in seconds) for the Hold Timer
established with the peer. The value of this object is
calculated by this BGP speaker, using the smaller of the
values in bgpPeerHoldTimeConfigured and the Hold Time
received in the OPEN message.
This value must be at least three seconds if it is not
zero (0).
If the Hold Timer has not been established with the
peer this object MUST have a value of zero (0).
If the bgpPeerHoldTimeConfigured object has a value of
(0), then this object MUST have a value of (0)."
REFERENCE
"RFC 4271, Section 4.2."
|
|