|
|
Description:
|
hwGlobalHealthStatus OBJECT-TYPE
SYNTAX INTEGER {ok(1), noncritical(2), critical(3)}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable summarizes the statuses of several key elements of the device.
OK:
- All temperature sensors are below the warning threshold (eg. < 85 C);
- All fans are running at >= 100 RPMs;
- Both power supplies are on;
- No panic dump exists in flash.
Non-critical:
- One or more temperature sensors is in the warning range (eg. >= 85 and < 100 C);
- A panic dump exists in flash.
Critical:
- One or more temperature sensors is in the failure range (eg. >= 100 C);
- One or more fans are running < 100 RPM;
- One power supply is off.
It is deprecated."
|
|
Disclaimer: The owner of this site does not warrant or assume any liability or responsibility for the accuracy, completeness, or usefulness of any information available on this page (for more information, please read the complete disclaimer).
All rights reserved, Orange © 2024 |