Description:
|
ss9000SaveConfiguration OBJECT-TYPE
SYNTAX INTEGER {
saveToPrimary(1),
saveToSecondary(2)
}
ACCESS write-only
STATUS mandatory
DESCRIPTION
"When this object is set, the device will copy the contents
of the configuration database to a buffer and save it to the
persistant store specified by the value of the object. The
save is performed asynchronously, and the snmp agent will continue
to respond to both gets and sets while the save is taking
place. A network management application may use the
ss9000SaveStatus object to determine when the asynchronous
save operation has completed."
|
|
Disclaimer: The owner of this site does not warrant or assume any liability or responsibility for the accuracy, completeness, or usefulness of any information available on this page (for more information, please read the complete disclaimer).