pktcEnEndPntRunFgnPotTsts OBJECT-TYPE
SYNTAX BITS {runFgnPotentialTsts(0), runHazardousPotTsts(1)}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This MIB object is used to initiate one or more test cases
associated with a supported foreign potential detection.
Thus, whenever one or more BITS corresponding to supported
foreign scenario potential detection mechanisms are set to
a value of '1', the MTA MUST enable those tests.
Once the tests are executed, the MTA MUST:
- set the corresponding bit to a value of '0'
- update the corresponding BITS in the MIB Objects
'pktcEnEndPntFgnTestValidity' and
'pktcEnEndPntFgnTestResults'.
If an SNMP SET attempts to set a bit corresponding to an
unsupported condition to a value of '1', then the MTA MUST
reject the entire SNMP SET and report an 'inconsistent
value' error.
Whenever a test is being run on an EndPoint the MTA MUST
set the corresponding 'ifOperStatus' MIB Object to a
value of 'testing(3)' for the whole duration of the test.
When the test is completed, the MTA MUST set the
ifOperStatus to the value corresponding to the current
state of the line.
Note: Whenever multiple tests are run, the ordering of the
tests or the results is vendor dependent and need not
necessarily follow the ordering of BITS in this MIB
Object."
|
|