coOptCtdDspCfgSignalDegradeThrshld OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
UNITS ".01dbQ"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This attribute configures the pre-FEC BER criteria and
duration over which the BER exceeds the SD threshold
before SignalDegrade is raised and an alarm is generated.
This threshold is not applicable when operating above the
FEC limit."
|
|