Description:
|
acVoiceAGCTargetEnergy OBJECT-TYPE
SYNTAX Unsigned32 (0..63)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Determines the signal energy value [-dBm] that the AGC (Automatic
Gain Control) attempts to attain.
Range = 0 to 63.
Access: Online.
AC INI-Param: AGCTARGETENERGY"
|
|